Technical conditions

Stage

  • Stage size minimum 10 x 10 m, i.e. depth x width between portals.
  • A cleared stage with no practitioners, a clean surface with no unevenness ready to lay the balletisol that the company brings with them.
  • Basic horizon in black.
  • Cleared passage spaces on the left and right side of the stage, also behind the horizon.
  • Minimum of 8 free strokes for hanging tulle, 2 x decorations and lights
  • There must be a space of at least 2.5 m between the horizon and the suspended pole
  • Functional intercom between the stage, lighting and sound.

Access to the stage

  • The day before xxxxx to allow access to the stage ideally from 16:00 to 21:00 (unloading of decorations, props, technical preparation – laying of balletisol, lighting preparation)
  • On the day of the performance … to allow access to the stage from 09:00 to 18:00 (space and dress rehearsal, ballet mopping, correction)

Technical preparation of the performance

  • During the preparation of the performance, the presence of a stage master is necessary, who is responsible for the stage and the work during the unloading and preparation of the performance.
  • Ensure that the ballet carpet is mopped with water without detergent one hour before the performance or after the end of the rehearsal.
  • During the performance, the assistance of a curtain man to operate the curtain and a stage master to operate the strokes, a soundman in the sound booth and a lighting man in the lighting booth is required.
  • Provide assistance to 1-2 local technicians in unloading and loading technical equipment and scenery before and after the performance.

Sound equipment

  • Auditorium: PA appropriate to the size of the space and number of spectators, min. 2x 500W
  • The stage: Monitors min. 2x 250W
  • Professional mixing console (min. 8 inputs, 4-band EQ, 2x AUX)
  • Connection of your own laptop (2x XLR or 2x large jack)
  • Possibility to connect an additional player or laptop.
  • During the technical preparation and the entire performance, the presence of a sound engineer is necessary.

Lighting equipment

  • Minimum of 48 regulated independent circuits.
  • Individual circuits are equipped with PC or Fresnel type reflectors.
  • Connection 380 V/63 A or 2 x 32 A near the stage
  • Spotlights for colouring the scene in orange and blue.
  • Spotlights placed in the following positions:
    1. front auditorium / left auditorium / right auditorium / stage bridge
    2. lion portal / right portal
  • Control of dimmers by DMX512 protocol – connect your own console.
  • When using the existing console, the possibility to use a minimum of 20 submasters.
  • A sufficient number of cables is a must.
  • During the technical preparation and performance, the presence of a lighting master is necessary
  • Spotlights for hanging and light towers will be brought by the ensemble’s own

Changing rooms

  • At least 1x changing room with showers – women, 1x changing room with showers – men, 1x changing room – children + entourage, toilet, ironing board with iron.
  • Tidy and heated performance areas (dressing rooms and stage).

Contacts:

Head of Technical Department: Viktor Svidró, email: viktor.svidro@gmail.com, tel. +420 774 543 727

Main lighting manager Tomáš Průcha, email: prucha.tomas@email.cz, tel: +420 730 900 462